Log in

View Full Version : Probe problem


smf
July 8th 07, 06:49 AM
I changed a bad probe on one cyl. My Hanger mate and I had about 8
spares.with very little time. I tried 6 of these and the same thing
happened. . When I snugged it up to the exaust pipe it would read 76..If I
took it out and put heat to it it worked ok. I did this to 5 or 6 and the
same thing happened. As soon as I snug it up it would not work. I can't
figure out what is happening. I know all the probes can't be bad .


any ideas


Steve

Morgans[_2_]
July 8th 07, 07:07 AM
"smf" > wrote in message
...
>I changed a bad probe on one cyl. My Hanger mate and I had about 8
>spares.with very little time. I tried 6 of these and the same thing
>happened. . When I snugged it up to the exaust pipe it would read 76..If I
>took it out and put heat to it it worked ok. I did this to 5 or 6 and the
>same thing happened. As soon as I snug it up it would not work. I can't
>figure out what is happening. I know all the probes can't be bad .
>
>
> any ideas

Try starting your engine after you install them. <(GD&R)>
--
Jim in NC

Bob Kuykendall
July 8th 07, 07:20 AM
Try heating one up and then touching it to the engine to see if the
problem has to do with a short to ground in the wires or gage.

smf
July 8th 07, 01:29 PM
I switched the probes and the problem went to the other cyl. It must be
some sort of ground problem because it doesn't quit working until the probe
is snugged up against the pipe.

steve
"Bob Kuykendall" > wrote in message
oups.com...
> Try heating one up and then touching it to the engine to see if the
> problem has to do with a short to ground in the wires or gage.
>