All right, I did some Google searching (sorry - I should have started
there)
and now suspect that my problem is in the grounding. But where in the
system? Can I fix this, or is it back to the avionics shop?
One thing you can do yourself is to isolate the jacks. Buy special fiber
washers
that have a double-thickness cylinder in the center. Remove each jack from
the
panel, re-drill or ream the hole in the panel to fit the center section of
the
isolation washer, and re-install the jack with a plain fiber washer in the
front.
The two fiber washers keep any metal parts of the jack from touching the
airframe,
so the only way the jack is grounded is the ground wire to the intercom.
Hate to be dense (not that I have a choice) but does the "double-thickness
cylinder in the center" mean something like a grommet?
Something like this?
http://www.marcorubber.com/grommets_commercial.htm
Thanks,
Michael
George Patterson
Love, n.: A form of temporary insanity afflicting the young. It is
curable
either by marriage or by removal of the afflicted from the
circumstances
under which he incurred the condition. It is sometimes fatal, but
more
often to the physician than to the patient.
They are called "shoulder washers", usally made of fiber or nylon.
Tom Pappano, PP-ASEL-IA
|