View Single Post
  #6  
Old November 11th 04, 06:04 PM
John Clonts
external usenet poster
 
Posts: n/a
Default


"WinstonCup" wrote in message
...
I have a 1978 C182 Q. I recently experienced my alternator turning off

and the
high voltage light coming on. I cycled the switch (1/2 master) and got it

to
reset every time, however, the interval between episodes varied. I had

the
Voltage Regulator and the Alternator replaced (new) and flew a couple of
flights since with no problem... until my last flight. Last flight it

happened
again. The Alternator switched off and the high voltage light came on. I
cycled the switch and it reset.

What else is causing this? Is it a bad switch? Loose connection at the

bus?

Has anyone else experienced this and what was your solution?

Any feedback is appreciated.


We had some problems in this area with our C210. There is EXCELLENT
diagnostic information readily available at www.zeftronics.com. (once you
figure out exactly which "type" you have). Our "main problem" was a failed
alternator (capacitor flopping around inside), but in the process we got rid
of a voltage drop across a circuit breaker connection and/or master switch
which had been causing our ammeter to "pulse" for as long as we've owned the
plane...

Good luck!
John Clonts
Temple, Texas
N7NZ