And more easily filtered when rectified for DC.
--
Gene Seibel
Hangar 131 -
http://pad39a.com/gene/plane.html
Because I fly, I envy no one.
"S Narayan" wrote in message ...
If memory serves, 3-phase power is more efficiently distributed, if all 3
phases have equal loads (either as a star or delta connected network), there
is no current in the return path (ground). That is, sum of all phases is 0.
So you can save one conductor for the same power transmitted. The generation
of 3 phase power is also easy and I believe it may also be more efficient in
terms of the generator design. The 400Hz transformer, compared to a 50/60Hz
one, requires less "iron" for the same flux generation (or less turns) since
the mutual inductance is proportional to frequency. Hence they are lighter.
However, they may have more losses due to eddy currents etc.