View Single Post
  #2  
Old May 7th 08, 07:30 PM posted to rec.aviation.owning,rec.aviation.piloting
Larry Dighera
external usenet poster
 
Posts: 3,953
Default Citabria Fuel-Flow Problem

On Wed, 7 May 2008 11:17:24 -0700 (PDT), quietguy
wrote in
:

The fuel system is not for inverted flight, so
no header tank -- two 18-gallon wing tanks with check valves to a
single vent on the left, crossflow pipes to the aft fuel manifold
under the baggage compartment and crossflow pipes to the forward fuel
manifold on the firewall. Caps are non-vented and the gaskets are
like new.

This A/C is drawing 3-4 times as much fuel from the left tank as from
the right and it's not crossflowing on the ground, even overnight.
We've made right patterns as well as lefts -- makes no difference. We
haven't done any extended S&L flight, just 11 NM to Plattsmouth, NE
for pattern work. The club's A&P has blown out the feed and vent
lines and got a good blast into the right tank from both. We're
getting a free flow of clean gas out of all four drains.



I'm not able to accurately visualize the fuel system piping from your
description, but has the A&P checked for a stuck check valve in the
vent piping?