On Aug 15, 2:34*pm, ryanglover1969 wrote:
Hey guys, I have a question about my Colibri. It has stopped recording
flights and when it turns on I get this message, "init memory" And it
says that the internal seal is not valid. I obviously have to get it
re-calibrated. But it has never stopped recording flight when it was
past it's re-calibration date.

Any ideas?

Thanks, Ryan


From page 29 of the Colibri manual:
"7 Problems
The following problems and messages might be seen:
· If INIT MEMORY appears after each power up, the lithium back up
battery is defective and should be
exchanged by an authorized LX service dealer.
· Unit ‘hangs’ during initialization. The most likely reason is a
corrupted TP/TSK data base. Carry
out the INIT MEMORY procedure (see below) and reload the data base. If
it happens again, then the
TP/TSK database may be corrupt - look for strange characters and
glitches. If LXe is used to load the
database, it automatically checks for corruption and will not allow it
to be loaded if corrupt. However,
third party programs may not provide this protection
· SEAL NOT valid message informs that the electronic data security
seal has operated. If this message
is seen in conjunction with the INIT MEMORY message, then the lithium
data back up is defective and
should be replaced. If the seal defect alone is reported, then a
possible reason is the use of third party
programs. Both these defects can be repaired by an authorized LX
service dealer. An unsealed unit
will continue to operate satisfactorily when the ESC button is
pressed, but the ‘G’ record will be
missing and any flight records downloaded will fail IGC validation.

Full manual can be downloaded at
http://www.lxnavigation.si/avionics/...ishVer0420.pdf.

Dan