View Single Post
  #5  
Old December 17th 12, 11:30 PM posted to rec.aviation.soaring
son_of_flubber
external usenet poster
 
Posts: 1,550
Default Wanted: a Digital Average Display for a Borgelt B40 Vario

On Monday, December 17, 2012 12:42:43 PM UTC-5, soartech wrote:


Does being in average mode change the audio? What is the averaging

time?


The audio averages over a 1-5 seconds period (running average). Period is factory set to 2 seconds. Adjustment of a pot must be done on the ground with access panel open to change the sample period. The "Average Mode" averages over 20 seconds. There is a momentary contact white push button on the face of the vario. Press the white button and the average is displayed on the dial. I believe that the 20 second average is stored and periodically (say every second) recomputed, so when you press the button, you immediately get the average for the last 20 seconds.

The suggested mode is to put a flip switch in parallel with the white button so that the 20 second running average is displayed and continually updated on the analog-like dial. The audio provides the 2 second average. The secondary mechanical vario displays something similar to the 2 second average on the analog dial.

The DAD is a numeric LCD that continually displays the 20 second average (the dial would display the 2 second average).