View Single Post
  #3  
Old August 22nd 13, 02:02 PM posted to rec.aviation.soaring
JJ Sinclair[_2_]
external usenet poster
 
Posts: 359
Default Sticking winter vario

On Wednesday, August 21, 2013 10:54:52 AM UTC-7, Jon Marshall wrote:
At 17:15 21 August 2013, Ian Reekie wrote:

I have a 10+ year old 57mm Winter vario that has just started


sticking when

it reaches its full positive deflection. A gentle tap on the glass


releases the needle.


I guess it will need a trip to Winter this winter (no joke


intended).



Out of curiosity, does anyone know what causes this sticking


and has

anyone successfully fixed this problem in the past.




Many thanks


Ian






Ian

Not an answer, but an endorsement of sending your vario to

Winter. We did all our mechanical instruments this year, a

somewhat lethargic 20 year old vario, a hatefully graunchy 20

year old altimeter and an ok ish 20year old asi.



All came back at very reasonable cost £120 each asi and vario

and £160 ish for the altimeter.

All came with a report in german and new form1. Now all work

as if new.



jon


I have ventured inside a sticking Winter vario and found the needle bent just enough to hit the glass at full deflection. A gentle nudge inward did the trick. Also, the needle can be centered by slightly bending the counterbalance located on the other side of the pivot point. I too have had great service from Winter. I packaged up about 10 real old instruments and got back 7 reconditioned instruments at a reasonable price.
JJ