According to my M/M:
High Pressure (Gear UP) pump puts out 2000 psi. It is turned off,
however, by a pressure switch @ 1800 +/- 100 psi.
Low Pressure (Down) is 500-800 PSI, just as your Maintenance people said.
Interesting note: The POH for my Seneca has a schematic which shows the pump
(gear up) operation as being turned off by the up-limit switches. The M/M
correctly shows the pump being shut off by the pressure switch.
Just hope that you never have to replace that pressure switch. It cost me
over 400 bucks (USED), a few years ago
"In Soo" wrote in message
news:EkQAd.11650$c%.10213@okepread05...
I have a quick question regarding system on a piper seneca. IT is !!!
what's
the pressure on Hydraulic system when the gear is uP? and how about when
it
is going down?
I check with the Mainteneace today, they said somewhere around 600~800
PSI,
but I always thought it was somewhere around 1500s. So, if anyone knows
the
answer, great! Thanks
In Soo hwang
|