View Single Post
  #52  
Old March 2nd 14, 09:28 PM posted to rec.aviation.soaring
Peter Wilson[_2_]
external usenet poster
 
Posts: 2
Default The

I load tasks from an oudie through a V7 to a red box flarm/logger. The red
box has a basic flarm display and communicates with it at max 19200 baud
(this can also be set to a lower figure and determines the speed of the
whole link). Consequently I have to set the V7 GPS and V7 PNA links to
19200 and it works fine.

Peter


At 16:53 01 March 2014, wrote
You need to ensure the baud speed for your logger is the same as the baud
speed for the PDA (as the V7 gives the PDA direct access to the logger

when
declaring a task). This should fix the problem

Chris


On Thursday, 27 February 2014 02:03:11 UTC, ES wrote:
Has anyone had luck uploading tasks from Oudie to V7? This topic isn't

discussed in the user guide, and I'm not having any luck repeating the
settings in the youtube video on the subject (device = "LXNAV - Nano",
interface = "COM4:", speed = "4800bps".



In the video, there is very quick connection and transfer.



When I try it (using the latest V7 firmware and Oudie version), I get

"Connecting" on the Oudie, and the communication icon on the V7, but
nothing else.



thanks



ted/ES