Yep, a little information.
Last Feb, the right fuel guage in my Cherokee 180 dropped to zero. We pulled the tank and found the float had "disappeared" from the sending unit arm. Closer look into the tank turned up the two pieces. CHEAP piece of plastic that had broken in two. I know this cheap piece of phenolic plastic (or whatever it is) couldn't cost more than 25 cents to manufacture. But since its "an instrument", you can't just get the part to stick on yourself. You have to ship the sending unit to an authorized repair station to stick a 25 cent part on it, test it, yellow tag it, and bill you $75+ for the job. But in my case, they screwed up -- didn't read the instructions with the sending unit, didn't remember our phone call, and rebuilt it. The cost if I remember right was right at $150. A phone call straightened that out and got the overcharge back on my credit card. But that's what the rebuild cost was. Air Parts of Lockhaven, Ct. Look them up on the web, they're there. Phone number is 800-443-3117.. Oh, and good luck finding a competitor to compare prices. They were the only place I found doing floats/sending units. See attached picture of rebuilt sending unit. I can't tell what rivet(s) you are talking about. Hope you can see them on that picture, its the only good pic of the unit before I installed it. Oh, and don't forget to get a new gasket. They'll throw away the old one when you ship it to them for rebuild. You'll want a new one on hand when the unit comes back. Chuck On Mon, 11 Jul 2005 23:10:08 GMT, Mike Spera wrote: When I had my tanks out in 1999 for the paint job and hose replacement, I also noticed stains from the sending units downward. I decided to replace the gaskets and reseal the things "while I was at it". The local wrenches said that getting the screws around the sending unit to seal completely was a crap shoot and the recommended method was to coat them with fuelube. They also said they were trying out using statoseal washers on the screws in an attempt to keep the screws from leaking. When I had the sending units out, I noticed that the resistive element had holes for rivets at both ends, however, only one end was riveted on both sending units. I thought it was odd but was not about to "experiment" by replacing the other rivet. My mechanic agreed. What was also odd was that the resistive element could wiggle back and forth pivoting on the single rivet. It struck me that eventually that would break from fatigue. But, I found no remnants of rivets in either tank and was hesitant to do any modification to this important system. Put everything back together and all worked fine for about 3 years or so. Then, the right gauge began reading about 2-3 gallons lower than the left gauge with a level plane and the same amount of fuel. It continued to read low by anywhere from 2-5 gallons low for about the next 2 years. Then, one day, the right gauge read 0. Really less than zero and on the peg. Getting out the repair manual, I saw that zero resistance should send the gauge to the "full" peg. I briefly grounded it and it did jump to "Full". For the next year, it worked as it had (around 4 gallons low). LAst couple of flights, it began reading all over the place, from less than zero to a few gallons low. Again, I briefly grounded the gauge and it flew up to zero. But this time, if remained flaky and is reading all over the place. By switching the sending units to the opposite gauges, the problem appears to indeed be with the right sending unit (or the wire from the terminal block to the sending unit). Checking the blade connector at the wing did not have any effect. I cannot remember if there was enough of a hole to get at the wire on the sending unit when you removed the inspection panel at the right landing gear. My hope is that the wire has worked loose at the sending unit terminal. I seem to recall JUST being able to touch the terminal if I put my arm in it up to the elbow (and it was NOT easy). Anyone else have any experience with these critters? Are they supposed to have 2 rivets holding the resistive element(one at either end)? Can you get at the terminal without pulling the tank? Are new sending units available for a reasonable price (maybe $200 or so)? Thanks for any suggestions. Please restrict any feedback to actual experience. Mike |
Thread Tools | |
Display Modes | |
|
|
![]() |
||||
Thread | Thread Starter | Forum | Replies | Last Post |
Time, running out of fuel and fuel gauges | Dylan Smith | Piloting | 29 | February 3rd 08 07:04 PM |
Is Your Airplane Susceptible To Mis Fu eling? A Simple Test For Fuel Contamination. | Nathan Young | Piloting | 4 | June 14th 04 06:13 PM |
Aerospace Logic Fuel Gauge | Scott G. | Owning | 10 | May 13th 04 10:07 PM |
Yo! Fuel Tank! | Veeduber | Home Built | 15 | October 25th 03 02:57 AM |
Cherokee Six Fuel problem | EDR | General Aviation | 1 | August 15th 03 03:03 PM |