My XP Hawk didn't have a filter upstream of the pump until I had to overhaul
the AH and DG, with carbon found in each instrument. I had a vac 'pump' failure some time previously. Hopefully the filter doers the trick during my next vac failure. -- regards Ron "Morgans" wrote in message ... "Mike Noel" wrote in message . .. OK, we now know the problem was a pinched hose, but there is some speculation that a failed vacuum pump can actually blow dust backwards into the vacuum instruments. The idea is that residual vacuum at the instruments allows the higher pressure at the failed pump to push the dust into the vacuum instruments. There is an STCd filter that can be placed between the instruments and the pump designed to prevent dust backflow if the pump fails. I thought vacuum systems had a check valve that prevented backwards moving air. No? If not, it sounds like they should. -- Jim in NC |