Retesting and filling oxygen tank.
I have had considerable difficulty getting FAA authorized oxygen service stations to retest and refill my 22 cu. ft. steel tank. It was originally purchased and installed in 1978 by Sailplane Repair Service in Ft. Collins, CO in accordance with a 337. Local stations here in Dallas, TX will not touch it without an assembly part number AND, even if it had one, they would only be able to service it if the P/N matched one for which they are authorized to service. My tank only shows the DOT 3AA1800 number stamped in the steel, but this is not the number required for the assembly. How do others in the U.S. get their tanks serviced, as I don't think the older tanks ever had such a number affixed? Do any owners of the newer aluminum tanks have similar problems with getting them serviced?
|
#2
|
|||
|
|||
Retesting and filling oxygen tank.
On May 1, 6:17*pm, lynn wrote:
I have had considerable difficulty getting FAA authorized oxygen service stations to retest and refill my 22 cu. ft. steel tank If there is a Technical Dive Shop in the area they may be able to help you. A Technical Dive shop will do custom mixing of gases including Helium and Oxygen for deep dives. Yes, they have the same DRY oxygen we have. Think about having a regulator freeze up at 300 feet below in the water. Locally we have a Technical Dive shop and they fill my tank in a matter of minutes, just carry it in. I think the last time they charged me about $3.50. They also recently started doing the pressure test. Also a Gas supply house for oxygen systems, should be able to do your testing and refill. ( about $35 the last time I went there) Locally the quickest and cheapest is the Dive shop. Yes, they have an impressive manifold system and give you 100% oxygen. Kevin 192 92 |
#3
|
|||
|
|||
Retesting and filling oxygen tank.
I go to the place that hydrotests oxy cylinders for welders and
medical users. I have yet to bring them a bottle that they would not or could not test. So, I'd think that the question becomes: Who is imposing the requirement that the test be done by an "FAA authorized oxygen service station?" If that verbiage is in the specific documentation or operating limitations for your sailplane, you might be stuck. But if not, just get it hydrotested at any reputable pressurized gas vendor and get on with life. Thanks, Bob K. |
#4
|
|||
|
|||
Retesting and filling oxygen tank.
Our club uses a local fire extinguisher shop. They do a good job for a good
price and they do it in house, ie, in a couple of days. When we've used industrial gas suppliers they have shipped the tank to a newarby city and it has taken a coupel of weeks. Note that all regulation for compressed gas tank come from the DOT. I don't think the FAA has any regulatory involvment with them. John Scott |
#5
|
|||
|
|||
Retesting and filling oxygen tank.
On May 1, 4:17*pm, lynn wrote:
I have had considerable difficulty getting FAA authorized oxygen service stations to retest and refill my 22 cu. ft. steel tank. It was originally purchased and installed in 1978 by Sailplane Repair Service in Ft. Collins, CO in accordance with a 337. Local stations here in Dallas, TX will not touch it without an assembly part number AND, even if it had one, they would only be able to service it if the P/N matched one for which they are authorized to service. My tank only shows the DOT 3AA1800 number stamped in the steel, but this is not the number required for the assembly. How do others in the U.S. get their tanks serviced, as I don't think the older tanks ever had such a number affixed? *Do any owners of the newer aluminum tanks have similar problems with getting them serviced? I think the other responses have the right answer. There's just no such thing as an "FAA Authorized Oxygen Service Station". What you are looking for is a simple DOT hydrotest shop. All compressed gas bottles require a current DOT stamp whether for aircraft or not. My guess is you explained what the O2 bottle is for and the particular shop is antsy about working on "airplane parts". My standard response to a question like, "What's it out of?" is to say it's a project I'd be happy to tell him all about but it'll take an hour. So far, no one has asked to hear the 'story'. |
#6
|
|||
|
|||
Retesting and filling oxygen tank.
On Tuesday, May 1, 2012 7:22:17 PM UTC-5, Bill D wrote:
On May 1, 4:17*pm, lynn wrote: I have had considerable difficulty getting FAA authorized oxygen service stations to retest and refill my 22 cu. ft. steel tank. It was originally purchased and installed in 1978 by Sailplane Repair Service in Ft. Collins, CO in accordance with a 337. Local stations here in Dallas, TX will not touch it without an assembly part number AND, even if it had one, they would only be able to service it if the P/N matched one for which they are authorized to service. My tank only shows the DOT 3AA1800 number stamped in the steel, but this is not the number required for the assembly. How do others in the U.S. get their tanks serviced, as I don't think the older tanks ever had such a number affixed? *Do any owners of the newer aluminum tanks have similar problems with getting them serviced? I think the other responses have the right answer. There's just no such thing as an "FAA Authorized Oxygen Service Station". What you are looking for is a simple DOT hydrotest shop. All compressed gas bottles require a current DOT stamp whether for aircraft or not. My guess is you explained what the O2 bottle is for and the particular shop is antsy about working on "airplane parts". My standard response to a question like, "What's it out of?" is to say it's a project I'd be happy to tell him all about but it'll take an hour. So far, no one has asked to hear the 'story'. Well, I was told by locals at our club,the place to go to in Dallas was "Safetech". They are an FAA Repair station (No. SMER451X) and do oxygen system repairs and servicing for all types of aircraft. Safetech emphatically told me no work could be done without the assembly part number and the number would have to be on their list of P/Ns approved for their shop by the FAA. So perhaps I misstated the shop as an "authorized FAA oxygen service station" and should have stated it as an "FAA Repair Station" but this is all semantics. In any case, I have a PIK-20D which has a Type Certificate issued by the FAA and I have always tried to stay legal when it comes to working on aircraft. So this is why I have not tried a dive shop or other non-FAA approved facility. So, if the consensus is aircraft oxygen systems can be serviced by just about any compressed gas facility, so be it. I just want to know for sure if this is the proper way to go in the eyes of the FAA. Even a well known supplier of oxygen systems (adverting in Soaring Mag) knew nothing about the requirements for servicing at an FAA repair station and said dive shop or fire extinguisher servicing facilities can be used with no hassle but do not mention it is for aviation use. Sounds as if this method is not legal. So how about it you legal beagles out there--just how does an aircraft owner get their oxygen system serviced legally? |
#7
|
|||
|
|||
Retesting and filling oxygen tank.
On May 2, 6:44*am, lynn wrote:
Well, I was told by locals at our club,the place to go to in Dallas was "Safetech". They are an FAA Repair station (No. SMER451X) and do oxygen system repairs and servicing for all types of aircraft... Keep in mind that the majority of aircraft that carry supplemental oxygen systems are corporate and executive transports typically costing a couple million dollars each. They are required to have oxygen systems as backups as spelled out in 14CFR§23.1441 and nearby sections. Note that I am not saying that these are the only aircraft that carry supplemental oxygen systems. Our gliders are an obvious exception, as are many personal aircraft outfitted for high-altitude cruising. But they are the majority. Anyhow, most FAA Repair stations that routinely handle supplemental oxygen systems specialize in the repair and maintenance of multimillion-dollar aircraft for the corporate sector. They cross all the Ts and dot all the Is that keep their corporate clients and their attorneys happy, charge commensurately, and everybody is happy. That works great for them. Not so much for us glider operators. The most cost-effective way to service your oxygen system is to learn to do it yourself. Even if you don't actually do it yourself, you have the knowledge required to hire an A&P or similarly qualified individual and tell them what needs to be done. But not how, A&Ps don't always like being told how even when you're right. A good place to start is learning the federal regulations that spell out the requirements for the certification, maintenance, and repair of light aircraft. Here are some good resources: * Advisory Circular AC43.13 is the general repair bible. It is advisory in nature, and does not spell out the rule of law. But it is a great guide, and the practices it spells out are generally within the rules. You can download AC43.13 from a variety of Internet sources. * To browse the federal regulations by part and section, you can use this link from the FAA website: http://ecfr.gpoaccess.gov/cgi/t/text...4/14tab_02.tpl * To search the federal regulations using keywords, use the Search link on the page above, and enter "14" for the Title. For gliders, the pilot certification stuff is in Part 61, the operational stuff is in Part 91, and the aircraft type certification stuff is in Part 23. Maintenance and repair of type certificated aircraft is spelled out in Part 43. There are other relevant Parts, of course, but those are the big ones. Thanks, Bob K. http://www.hpaircraft.com https://www.facebook.com/pages/HP-24...t/200931354951 |
#8
|
|||
|
|||
Retesting and filling oxygen tank.
On 5/1/2012 3:17 PM, lynn wrote:
I have had considerable difficulty getting FAA authorized oxygen service stations to retest and refill my 22 cu. ft. steel tank. It was originally purchased and installed in 1978 by Sailplane Repair Service in Ft. Collins, CO in accordance with a 337. Local stations here in Dallas, TX will not touch it without an assembly part number AND, even if it had one, they would only be able to service it if the P/N matched one for which they are authorized to service. My tank only shows the DOT 3AA1800 number stamped in the steel, but this is not the number required for the assembly. How do others in the U.S. get their tanks serviced, as I don't think the older tanks ever had such a number affixed? Do any owners of the newer aluminum tanks have similar problems with getting them serviced? I'm under the impression that most gliders don't have an oxygen system installed in them; instead, the pilot uses a "portable" system in the glider, carefully ensuring the bottle and regulator are secured when they are carried in the glider during flight. My portable system is an oxygen bottle that can be easily removed in less than a minute without using any tools, and a Mountain High regulator that can be popped off the Dual-Lock fasteners in 10 seconds. The bottle goes to any place that does testing and will affix the correct DOT numbers; the regulator goes back to Mountain High if it has a problem. Do you have something different than this? If not, stop taking it to the FAA shops, as they are not the appropriate place to work on it; if it is different, describe it for us. -- Eric Greenwell - Washington State, USA (change ".netto" to ".us" to email me) |
#9
|
|||
|
|||
Retesting and filling oxygen tank.
On Wed, 02 May 2012 08:44:16 -0500, lynn wrote:
So how about it you legal beagles out there--just how does an aircraft owner get their oxygen system serviced legally? Lynn, OK. I'll bite. I don't think I'm a "legal beagle", but I am a bit of an FAR-nerd, so I'll expose myself to collective ridicule and attempt to answer your question completely. The first question to ask (as others have pointed out) is whether your oxygen tank is considered (legally) to be part of your aircraft or not. If the tank is not listed in your operating limitations section as a piece of required equipment, and has not been included in any subsequent 337 forms as something that is installed in the aircraft, then it is not part of your aircraft. In general, if something is not part of your aircraft, then the FAA does not care about who inspected it or how it was inspected. If it is not installed as a part of the aircraft but is carried aboard the aircraft, then it is "cargo." The FAA has regulations about carrying oxygen cylinders as cargo, but these apply to inaccessible cargo areas of transport-category aircraft. So, on a private, Part 91 flight the FAA does not care about what type of oxygen tank you may have aboard. On the other hand, the Department of Transportation (DOT) does have regulations about the transport of compressed gas cylinders. I am not an expert on DOT regulations, but to my knowledge these regulations are not specific to aviation oxygen (as opposed to any other type of compressed oxygen). Therefore, any place (dive shop, welding supply shop, etc.) that is certified to test and inspect compressed gas cylinders according to the DOT requirements should be able to inspect and test your cylinder. There is nothing "illegal" or shady about this. It's a DOT regulation, so any shop that meets DOT requirements (see below for discussion of these requirements) can legally certify your cylinder (whether or not it's used in aviation). If (and I highly doubt that this is the case with your Pik 20) the oxygen cylinder is required equipment, then the manufacturer would be obliged to publish inspection criteria and servicing instructions, and then you'd be obliged to follow these procedures. In the absence of any specific guidance from the manufacturer, the Aircraft Maintenance Technician (e.g. A&P or IA) performing maintenance or inspection of the oxygen system would follow the FAA's procedures as outlined in AC 43.13-1B "Acceptable Methods, Techniques, and Practices - Aircraft Inspection and Repair". In Chapter 9 this Advisory Circular describes how an AMT should inspect and service installed oxygen cylinders, to wit: 9-51. SERVICE OXYGEN CYLINDERS. REQUIREMENTS (Ref 49 CFR 173.34 e, 16). Standard-weight cylinders must be hydrostatic tested at the end of each 5-year period (10 years if it meets the requirements in 49 CFR 173.34 e, 16). This is a Department of Transportation (DOT) requirement. Thesecylinders carry an ICC or DOT 3AA 1800 classification and are suitable for the use intended. Lightweight cylinders must be hydrostatic tested every 3 years, and must be retired from service after 24 years or 4,380 pressurizations, whichever occurs first. These cylinders carry an ICC or DOT 3 HT 1850 classification and must be stamped with the approval after being inspected. (Ref. 49 CFR 173.34 e, 15). Note that the FAA's guidance refers to 49 CFR which is the Transportation code. The rules in 49 CFR 173.34 are pretty long, but your question concerned who can do this inspection, not necessarily how it is done, so I'll dispense with quoting the "how" and focus on the "who". 49 CFR 173.34 (e) (2) (i) says:" "No person may mark a cylinder with a test date or retester identification number,or otherwise represent that a DOT specification or exemption cylinder has been retested under this section, unless that person holds a current retester identification number issued by the Associate Administrator for Hazardous Material Safety and operates in compliance with the terms of the retester identification number issuance letter." So, to finally answer your question of "how does an aircraft owner get their oxygen system serviced legally?" I can offer this explanation. If you have an installed oxygen system, all servicing must be done according to the manufacturers instructions and/or AC 43.13-1B. 43.13-1B says that the testing and marking of these cylinders must be done according to 49 CFR 173.34, which in turn specifies that the hydrstatic testing and marking can only be done by someone who holds a current retester identification number. So, the AMT would be obliged to take the cylinder to someone who holds this retester identification number. This could be an aviation-specific shop, or not. As long as they hold this identification number and are operating under the terms of the issuance letter for this number, then they can certify the tank. Your A&P would then note this inspection in the aircraft logs, and everyone is happy. On the other hand, if the oxygen system isn't an installed system, then there is no legal requirement under the Federal Aviation Regulations (anymore than there is a requirement for you to inspect a duffel bag or any other item of cargo). However you still need to comply with 49 CFR 173.34 since the tank will be carried aboard an aircraft as cargo. In this case, you should seek out someone who holds a retester identification number as prescribed in 49 CFR 173.34 (e) (2) (i) and ask them to inspect and certify your tank. Then, you're good to go. I hope this is "legal-beagly" enough. --Stefan -- Stefan Murry |
#10
|
|||
|
|||
Retesting and filling oxygen tank.
If the tank is "portable", and you will be having it hydro tested
locally, I suggest NOT using a welding supply place unless they test on-site. If they throw a bunch of bottles in a truck to send off for testing, your nice bottle will not come back looking the same. bumper |
|
Thread Tools | |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
Saturn V S-IC-T (static test stage) fuel tank assembly is mated to the liquid oxygen (LOX) tank 6416666.jpg | [email protected] | Aviation Photos | 0 | April 12th 07 01:33 AM |
Saturn I Liquid-Oxygen (LOX) Tank 6000382.jpg | [email protected] | Aviation Photos | 0 | April 10th 07 09:59 PM |
oxygen tank | Lignan Christian | Soaring | 10 | February 9th 06 10:52 PM |
filling Oxygen tanks | Bruce McFadden | Piloting | 40 | January 3rd 05 03:25 AM |
Filling oxygen tanks | Bruce McFadden | Owning | 49 | December 28th 04 11:41 PM |