Has anyone experienced both "P" leads in a D2000 shorting out against
the back of the case? It appears this may have happened in a C172
(1979) as there are arc marks at the connectors. Looks like a gasket
should have been install but none is there? Any comments appreciated.
October 18th 03, 01:01 AM
Chick Urick > wrote in message >...
> Has anyone experienced both "P" leads in a D2000 shorting out against
> the back of the case? It appears this may have happened in a C172
> (1979) as there are arc marks at the connectors. Looks like a gasket
> should have been install but none is there? Any comments appreciated.
You've got me swinging.
The "P" leads on D2000 screw into the back side of the capacitors last
time I checked.
It is not uncommon for the wires from the capacitors to the points
getting pinched in between the case halves, that's typically an
installation/assembly issue.
The only "gasket" that I'm familiar with goes between the halves, and
is only used on pressurised installs.