View Full Version : 2 HSI's with 1 gyro/fluxgate?
Dico
May 16th 06, 10:26 PM
Hello,
Our panel has a King HSI in it aswell as a 2nd ILS/GS indicator. If we
put in a 2nd HSI or EHSI, can they both run off one gyro/fluxgate? Or
do we need a gyro/fluxgate for each?
-dr
karl gruber
May 16th 06, 11:11 PM
I have an HSI and an indicator running off one gyro, so...yes...one gyro can
run both.
Karl
ATP CFI ETC
"Curator" N185KG
"Dico" > wrote in message
ups.com...
> Hello,
>
> Our panel has a King HSI in it aswell as a 2nd ILS/GS indicator. If we
> put in a 2nd HSI or EHSI, can they both run off one gyro/fluxgate? Or
> do we need a gyro/fluxgate for each?
>
> -dr
>
tom418
May 17th 06, 12:44 AM
FWIW:
On a B727, there is a provision for switching Captain's or F/O's RMI to the
"other pilot's" compass system. One would select "Both on Comp1" or "Both on
Comp2"
So, it seems that you can drive 2 RMI's or whatever off one fluxgate.
"Dico" > wrote in message
ups.com...
> Hello,
>
> Our panel has a King HSI in it aswell as a 2nd ILS/GS indicator. If we
> put in a 2nd HSI or EHSI, can they both run off one gyro/fluxgate? Or
> do we need a gyro/fluxgate for each?
>
> -dr
>
Prime
May 17th 06, 06:30 AM
"Dico" > posted the exciting message
ups.com:
> Hello,
>
> Our panel has a King HSI in it aswell as a 2nd ILS/GS indicator. If we
> put in a 2nd HSI or EHSI, can they both run off one gyro/fluxgate? Or
> do we need a gyro/fluxgate for each?
>
> -dr
>
>
You need another flux capacitor along with a Mr. Fusion for the correct
power levels.
Dico
May 17th 06, 01:30 PM
Perfect.... thanks for your help everyone!
Dico wrote:
> Perfect.... thanks for your help everyone!
Actually, I *think* the answer is no. I don't have the books in front
of me, but the HSI (actually, the circuit card in the gyro) generates
the excitation signal to the fluxgate. Since the response is only a
phase issue with respect to the excitation signal, I don't see how you
could couple it to two HSI's. [Actually, since it is only used to
maintain alignment over the long-term, I guess you could rig a switch
that hooked the flux gate to one HSI for a few minutes, then the other,
then back again. Not very elegant.]
Now all this is for the old King KCS-55 system. There may be something
newer available.