A aviation & planes forum. AviationBanter

If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below.

Go Back   Home » AviationBanter forum » rec.aviation newsgroups » Owning
Site Map Home Register Authors List Search Today's Posts Mark Forums Read Web Partners

AvTek Pulsar Installation PIREP (or "Why I'm Not an A&P")



 
 
Thread Tools Display Modes
  #1  
Old November 1st 07, 03:21 AM posted to rec.aviation.owning
Margy Natalie
external usenet poster
 
Posts: 476
Default Was: "Why I'm Not an A&P" - Now: Fixin' Stuff

Mike Spera wrote:
O.K. I have a good one. The doorbell mounted high on a soffit overhead
in the kitchen. What could they POSSIBLY screw up?

When I tore down the drywall (ALL 4 LAYERS - the DIP****S just kept
piling it on for the backsplash) I found the wiring for the doorbell.

It was an old 110v system. They used zip cord (brown 18 gauge lamp cord)
STAPLED TO THE 2X4 stud. It was wired into one of the legs to the
electric stove. Big lug with electrical tape around it. This was on a 50
amp circuit breaker. Remember that lamp cord is rated for 8 amps or so.

I found the doorbell shorted, the zipcord completely devoid of the
insulation because the short had cooked it off, and the remaining
strands of wire burned/buried into the scorched and blackened 2X4. I
have no idea how this did not start a fire.

I also found a "new" outlet some bubba installed. 2 pieces of insulated
wire strung between the drywall and studs, around and inside corner to
the new outlet. Real nice.

Finally the topper. They turned the former laundry room into a bathroom,
complete with shower. For an exhaust fan, they plastered in the wrong
sized unit into a big hole high up on a wall (2+ inches of plaster
oozing out the back). Now, the $6000 punchline. Since it was too much
trouble to run the vent hose properly (through a roof vent), they simply
left it hanging IN THE DROP CEILING COLD AIR RETURN. The warm wet air
from the bathroom was being pumped into this drop ceiling where it went
straight into the roof insulation and finally the roof decking. 80+
sheets of rotted decking (an additional $6k for the roof) because Bubba
Jackass did not have the brains to know that you NEVER run a bathroom
vent ANYWHERE but out of the house, preferably out the roof.

What have you guys seen? Don't limit this to your house, this is an
aviation group. I'm sure we have some real winners in the airplane
category...


Can't wait
Mike

We took out a DG that had a piece of masking tape that said "$5" on it.
Does that count? BTW the system had NO filters, at all.

Margy
 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Similar Threads
Thread Thread Starter Forum Replies Last Post
The Good, the Bad, the Ugly: AirGizmo PIREP, PS Engineering CD/Intercom woes, XM "service" Jay Honeck Owning 34 December 15th 06 03:02 AM
Old polish aircraft TS-8 "Bies" ("Bogy") - for sale >pk Aviation Marketplace 0 October 16th 06 07:48 AM


All times are GMT +1. The time now is 05:43 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 AviationBanter.
The comments are property of their posters.