Mike Spera wrote:
O.K. I have a good one. The doorbell mounted high on a soffit overhead in the kitchen. What could they POSSIBLY screw up? When I tore down the drywall (ALL 4 LAYERS - the DIP****S just kept piling it on for the backsplash) I found the wiring for the doorbell. It was an old 110v system. They used zip cord (brown 18 gauge lamp cord) STAPLED TO THE 2X4 stud. It was wired into one of the legs to the electric stove. Big lug with electrical tape around it. This was on a 50 amp circuit breaker. Remember that lamp cord is rated for 8 amps or so. I found the doorbell shorted, the zipcord completely devoid of the insulation because the short had cooked it off, and the remaining strands of wire burned/buried into the scorched and blackened 2X4. I have no idea how this did not start a fire. I also found a "new" outlet some bubba installed. 2 pieces of insulated wire strung between the drywall and studs, around and inside corner to the new outlet. Real nice. Finally the topper. They turned the former laundry room into a bathroom, complete with shower. For an exhaust fan, they plastered in the wrong sized unit into a big hole high up on a wall (2+ inches of plaster oozing out the back). Now, the $6000 punchline. Since it was too much trouble to run the vent hose properly (through a roof vent), they simply left it hanging IN THE DROP CEILING COLD AIR RETURN. The warm wet air from the bathroom was being pumped into this drop ceiling where it went straight into the roof insulation and finally the roof decking. 80+ sheets of rotted decking (an additional $6k for the roof) because Bubba Jackass did not have the brains to know that you NEVER run a bathroom vent ANYWHERE but out of the house, preferably out the roof. What have you guys seen? Don't limit this to your house, this is an aviation group. I'm sure we have some real winners in the airplane category... Can't wait Mike We took out a DG that had a piece of masking tape that said "$5" on it. Does that count? BTW the system had NO filters, at all. Margy |
Thread Tools | |
Display Modes | |
|
|
![]() |
||||
Thread | Thread Starter | Forum | Replies | Last Post |
The Good, the Bad, the Ugly: AirGizmo PIREP, PS Engineering CD/Intercom woes, XM "service" | Jay Honeck | Owning | 34 | December 15th 06 03:02 AM |
Old polish aircraft TS-8 "Bies" ("Bogy") - for sale | >pk | Aviation Marketplace | 0 | October 16th 06 07:48 AM |